{"product_id":"emx-ult-mvp-2e","title":"EMX Two Channel Multi-Voltage Vehicle Loop Detector EU Wiring | EMX-ULT-MVP-2E","description":"\u003ch2\u003eEMX Two Channel Multi-Voltage Vehicle Loop Detector EU Wiring | EMX-ULT-MVP-2E\u003c\/h2\u003e\n\u003cp\u003eThe ULTRALOOP® two-channel multi-voltage vehicle loop detector combines small\u003cbr\u003esize with a 12VDC to 240VAC input range.\u003c\/p\u003e\n\u003cp\u003eThe ULT-MVP-2 provides relay contact outputs indicating vehicle presence, pulse, AB logic (directional mode), or the new EMX feature, Detect-On-Stop™ (DOS®) for each channel. The ULT-MVP-2 features automatic sensitivity boost (ASB) and infinite or normal (5 min.) presence.\u003c\/p\u003e\n\u003cp\u003eThe detector is easily installed and has user-friendly features that simplify set-up, operation, and troubleshooting. Sensitivity selection is simplified by the ULTRAMETER™ display that indicates the appropriate sensitivity setting with the vehicle positioned on the loop. The 10 sensitivity settings allow for finer adjustment of the detection level, while the 4 frequency selections provide greater flexibility in preventing crosstalk in multi-loop applications.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003ePresence\/pulse output\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAB logic\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDetect-On-Stop\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eABS\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNormal\/infinite presence\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eConnections\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003ePower: 1 \u003c\/li\u003e\n\u003cli\u003ePower: 2\u003c\/li\u003e\n\u003cli\u003eChannel 1 loop: 3\u003c\/li\u003e\n\u003cli\u003eChannel 1 loop: 4\u003c\/li\u003e\n\u003cli\u003eChannel 2 loop: 5\u003c\/li\u003e\n\u003cli\u003eChannel 2 loop: 6\u003c\/li\u003e\n\u003cli\u003eChannel 2 NO contact: 7\u003c\/li\u003e\n\u003cli\u003eChannel 2 common contact: 8\u003c\/li\u003e\n\u003cli\u003eGround: 9\u003c\/li\u003e\n\u003cli\u003eChannel 1 NO contact: 10\u003c\/li\u003e\n\u003cli\u003eChannel 1 common contact: 11\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eManufacturer's Warranty\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e2 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eTechnical Specifications\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eSensitivity: 10 levels, 0-9\u003c\/li\u003e\n\u003cli\u003eULTRAMETER™ Display: Indicates optimum sensitivity level, 0-9 Diagnostic aid\u003c\/li\u003e\n\u003cli\u003eLoop Frequency: 4 settings (low, med-low, med-hi, high)\u003c\/li\u003e\n\u003cli\u003eLoop Inductance: 20…2000µH (Q factor \u0026gt; 5)\u003c\/li\u003e\n\u003cli\u003eGrounded Loop: Isolation transformer allows operation with poor quality loops\u003c\/li\u003e\n\u003cli\u003eAutomatic Tuning: Detector tunes to loop on power-up and following frequency count function\u003c\/li\u003e\n\u003cli\u003eEnvironmental Tracking: Automatic compensation\u003c\/li\u003e\n\u003cli\u003eSurge Protection: Loop circuitry protected by surge suppressors\u003c\/li\u003e\n\u003cli\u003ePresence Relay: Loop circuitry protected by surge suppressors\u003c\/li\u003e\n\u003cli\u003eOutput B Relay: SPST relay contact (form A)\u003c\/li\u003e\n\u003cli\u003eContact Ratings: 1A @ 24VDC…120VAC\u003c\/li\u003e\n\u003cli\u003ePower \/ Loop Fault Indicator: Green LED\u003c\/li\u003e\n\u003cli\u003eDetect \/ Frequency Count Indicator: Red LED\u003c\/li\u003e\n\u003cli\u003eDetect-On-Stop™: Requires vehicle to stop for a minimum of 1 second (1-2s typical)\u003c\/li\u003e\n\u003cli\u003eASB (Automatic Sensitivity Boost): Increases sensitivity after initial detection to prevent dropout due to high-bed vehicles\u003c\/li\u003e\n\u003cli\u003ePower: 12VDC…24VDC, 24VAC\u003c\/li\u003e\n\u003cli\u003eOperating Current: 15mA standby \/ 45mA detect\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -40˚C…82˚C (-40˚F…180˚F) 0…95% relative humidity\u003c\/li\u003e\n\u003cli\u003eDimensions (L x W x H):\u003cspan\u003e \u003c\/span\u003e73mm (2.9”) x 38mm (1.2”) x 78mm (3.1”)\u003c\/li\u003e\n\u003cli\u003eWeight: 0.25 lbs. (113 g)\u003c\/li\u003e\n\u003cli\u003eHousing: ABS plastic, IP30\u003c\/li\u003e\n\u003cli\u003eConnections: Socket mount - 11-pin male (JEDEC B11-88)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eVideos\n\u003cdiv style=\"left: 0; width: 100%; height: 0; position: relative; padding-bottom: 56.338%;\"\u003e\u003ciframe src=\"https:\/\/player.vimeo.com\/video\/1248384794?app_id=122963\" style=\"top: 0; left: 0; width: 100%; height: 100%; position: absolute; border: 0;\" allowfullscreen scrolling=\"no\" allow=\"encrypted-media *;\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv style=\"left: 0; width: 100%; height: 0; position: relative; padding-bottom: 56.338%;\"\u003e\u003ciframe src=\"https:\/\/player.vimeo.com\/video\/1248377557?app_id=122963\" style=\"top: 0; left: 0; width: 100%; height: 100%; position: absolute; border: 0;\" allowfullscreen scrolling=\"no\" allow=\"encrypted-media *;\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003ch5\u003eProduct Literature\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0537\/7916\/9453\/files\/EMS-ULT-MVP-2-Spec-Sheet.pdf?v=1753718004\" target=\"_blank\"\u003eEMX ULTRA-MVP-2 Spec Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0537\/7916\/9453\/files\/EMX-ult-mvp-2-Manual.pdf?v=1626796318\"\u003eEMX ULTR-MVP-2 Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/h5\u003e","brand":"EMX","offers":[{"title":"Default Title","offer_id":41314163294381,"sku":"EMX-ULT-MVP-2E","price":157.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0537\/7916\/9453\/files\/EMX-Two-Channel-Multi-Voltage-Vehicle-Loop-Detector-ULT-MVP-2.jpg?v=1753720662","url":"https:\/\/saralyxlr.shop\/products\/emx-ult-mvp-2e","provider":"All Security Equipment","version":"1.0","type":"link"}